Dual-string high-capacity C&I cabinet
250 kW / 522.5 kWh Battery Storage CabinetContainer-class energy density without leaving the cabinet format.
A dual-string, dual-PCS outdoor LFP cabinet delivering 250 kW and 522.5 kWh for larger commercial loads and longer dispatch windows.

Application fit
Start with the operating duty.
The 250 kW / 522.5 kWh platform uses two 314 Ah LFP strings and two 125 kW PCS power blocks in one larger enclosure. It fills the gap between compact cabinets and centralized container systems, while maintaining a 400 V site interface.
Open the RFQ input checklistIntegrated architecture
Four layers form the starting platform.
The commercial scope still needs a project responsibility matrix covering every external interface.
Dual battery strings
Two parallel 260-series LFP strings provide 522.5 kWh rated energy.
Dual PCS blocks
Two 125 kW bidirectional PCS units combine for 250 kW rated AC output.
Integrated controls
BMS and EMS coordinate both strings, PCS dispatch, alarms and site communication.
Outdoor platform
Liquid cooling, IP54 cabinet, C3 coating and fire suppression support C&I deployment.
Technical specifications
Documented configuration data.
Values are taken from the supplied manufacturer specification. Final purchase, installation and acceptance must use the approved project datasheet, drawings and test documents.
| Group | Parameter | Documented value |
|---|---|---|
| Battery | Cell chemistry and format | LFP, 3.2 V / 314 Ah |
| Battery | Rated energy | 522.5 kWh |
| Battery | Nominal DC voltage | 832 V |
| Battery | DC voltage window | 650-949 V |
| Battery | String arrangement | 2P260S |
| PCS | Rated AC output | 250 kW |
| PCS | Maximum AC output | 275 kW |
| PCS | Rated AC voltage | 400 V; 230/400 V off-grid |
| PCS | Maximum output current | 400 A |
| PCS | Frequency and power factor | 50/60 Hz; 0.99 |
| PCS | Maximum discharge efficiency | 98.5% |
| System | Charge/discharge rate | 0.5C |
| System | Base enclosure dimensions | 1940 x 1504 x 2555 mm |
| System | Interface envelope | 1940 x 1574 x 2705 mm |
| System | Approximate weight | 5.4 t |
| System | Communications | CAN / RS485 / Ethernet / 4G |
| Environment | Altitude | Up to 3000 m; derating review above 2000 m |
| Environment | Enclosure | IP54; C3 corrosion protection |
| Environment | Operating temperature | -20 C to 55 C |
| Environment | Relative humidity | 0-95%, non-condensing |
| Thermal | Cooling | Intelligent liquid cooling |
| Safety | Fire suppression | Perfluorohexanone system |
Scope boundary
Separate product from project.
A comparable quotation makes included equipment and external responsibilities explicit.
Starting equipment scope
Documented platform
- Two LFP battery strings and DC collection
- Two 125 kW PCS power blocks
- BMS and EMS coordination
- Intelligent liquid-cooling system
- Detection and fire-suppression system
- Outdoor enclosure and auxiliaries
Project boundary
Confirm before quotation
- Single-line diagram and parallel cabinet architecture
- Site transformer and 400 V switchboard rating
- Fault level and protection coordination
- Cable entry, lifting path and foundation load
- Operating reserve and degradation allowance
- Factory tests, shipment split and field commissioning
Buyer questions
Resolve these points before ordering.
Use the answers to narrow the design; use the final project documents to release the order.
When should this model be selected instead of two small cabinets?
Use the 250 kW platform when a consolidated dual-string enclosure better fits the footprint, cable routing and maintenance plan. Redundancy and transport strategy should still be compared.
Can multiple units operate in parallel?
A multi-cabinet project is possible, but EMS hierarchy, metering, AC bus rating, protection, communications and transformer capacity must be engineered for the total plant.
Is 4G the only remote communication option?
No. The documented interfaces include CAN, RS485, Ethernet and 4G. The final protocol map and remote access policy are project-specific.
Does the quoted size include all external interfaces?
The 1940 x 1504 x 2555 mm figure is the base enclosure. The larger interface envelope accounts for lifting and external fire-water details.
Buyer engineering guides
Check the assumptions around this configuration.
Connect the product data to measured demand, electrical design, safety evidence and quotation scope.
Compare adjacent configurations
Continue the product review.
Compare power, duration, interface and project boundary before selecting a starting platform.
Product quick RFQ
Match this configuration to the real site.
Send the country, operating target and the first project requirements. The product title and source page are attached automatically.